  • GE B30 | Bus Differential System

    Cost-effective, low-impedance, biased bus differential protection for up to six feeders The B30 features integrated protection, control and metering for MV, HV and EHV busbars, providing cost-effective, feature-focused busbar protection. Use the B30 to protect busbars with up to 6 feeders with up to two three-phase differential zones. The B30 is a cost-effective alternative to high-impedance schemes, ideal for breaker-and-half bus schemes, with integrated feeder backup protection and metering.

    View More
  • P346 Small Generator Protection with Differential

    Advanced generator management relay with differential protection for small/medium generators Comprehensive generator and transformer protection and condition monitoring Support for a wide range of communication options including MODBUS, IEC60870-5-103, DNP 3.0 and IEC61850

    View More
  • P741 - Busbar Differential Relay (Central Unit)

    Busbar scheme for centralized or distributed applications up to 8 zones + Check Zone and 28 bays. Adaptable to any busbar configuration. True sample based sub-cycle operation. Fully redundant communications between CU and PU’s. IEC 61850-9-2 LE process bus (with P743).

    View More
  • P747 – Busbar Differential Relay

    Complete protection for MV and HV Busbar configurations with up to 4 zones and 18 feeders Interoperable with all classes of CT: IEEE, IEC, air-gapped, non-gapped - and CTs with moderate knee point voltage 10 integrated function keys, tri-color LEDs, and graphical programmable logic permit the creation of comprehensive schemes, tailored to your needs IEC 61850 redundant Ethernet, supporting self-healing ring, RSTP, dual homing or PRP/HSR IEC62439 HSR compliant IEC61850 Ed 1

    View More
  • P742 - Busbar Differential Relay (Peripheral Unit)

    Peripheral Unit used with P741. 40TE case with standard IO. Backup protection functions (50 N&P/51 N&P/50ST P&N).

    View More
  • P746 – Busbar Differential Relay

    Complete protection for MV and HV Busbar configurations with up to 2 zones and 18 feeders Option of conventional VT or IEC 61850-9-2LE compliant sampled value Process Bus 10 integrated function keys, tri-color LEDs, and graphical programmable logic permit the creation of comprehensive schemes. IEC 61850 redundant Ethernet, supporting self-healing ring, RSTP, dual homing or PRP/HSR IEC62439 HSR compliant IEC61850 Ed 1

    View More
  • P743 - Busbar Differential Relay (Extended Peripheral Unit)

    Peripheral Unit used with P741. IEC 61850 Ed.1 communication. IEC 61850-9-2 LE process bus ready. 60TE case with increased IO. Backup protection functions (50 N&P/51 N&P/50ST P&N).

    View More
  • MFAC: High – Speed Differential Protection Relay

    MFAC 14 when only earth fault protection is required, MFAC 34 provides both phase and earth fault protection. Applications including generators, reactors, busbars, motors and the individual windings of power transformers. Ensuring high stability with through faults, with 'tuned to rated frequency' technique and a wide settings range Fast and reliable due to its simple electromechanical construction

    View More
  • MCAG High - Speed Differential Protection

    Current-calibrated busbar differential relay highly-tuned to the fundamental to prevent spurious operation Attracted armature design with simple and robust construction High impedance protection principle High stability during through faults, Operation is fast and reliable (25ms at 5 x setting)

    View More
  • MVTP – Buswire Supervision Relay

    Single and 3-phase Models for continuous Buswire supervision Used in high impedance type Busbar protection schemes Detects open-circuited Buswire as well as open-circuited main current transformers. Integral Buswire shorting facility

    View More
  • GE B90 | Low Impedance Bus Differential System

    Secure, dependable and scalable bus differential protection system for LV, HV and EHV busbars

    View More