Products

Generator

Generator

  • GE GPM-F | Field Ground Protection Module

    The field ground protection module, GPM-F works in combination with the Multilin G60 to detect ground faults in the field winding of the generator. Providing application flexibility, the field ground protection module can be configured for either single point injection or double point injection based on application requirements. The solution includes: two stage field ground detection, injected voltage and current supervision, brush lift-off detection, field over and under current elements and field ground fault location.

    View More
  • GE 489 l Generator Protection System

    The SR489 Generator Protection System, a member of the SR family of relays, provides protection, control and advanced communications in a cost effective industry leading draw-out construction. Designed for small and medium sized generators, the 489 delivers advanced protection including generator stator differential protection. The 489 also includes detailed diagnostic information allowing for reduced troubleshooting time.

    View More
  • GE G30 | Generator Protection System

    Protection for small to medium generators, combined generators and transformers Built on the industry-leading UR platform, the G30 provides advanced protection for small to medium-sized steam, hydraulic and combustion-turbine generators. The G30 is also well suited for applications where both the generator and transformer are in the same zone of protection, providing the required protection in one device. The G30 provides advanced communication with an integrated managed Ethernet switch, while supporting standard communication protocols including IEC 61850.

    View More
  • GE G650 | Generator Protection and Control System

    The G650 is a Distributed Generation Protection and Control Relay designed for complete protection of small to medium sized generators as well as operate as a control system for distributed generation interconnections. The G650 provides a cost effective and scalable solution that allows for tailoring your protection, communications, and I/O requirements to meet the needs of your specific application.

    View More
  • 889 Generator Protection System

    Primary or backup protection for generators Suitable for combined generator and in-zone transformer differential protection Support for a wide range of communications protocols, network architectures, and time synchronization, including Modbus, DNP 3.0, IEC 61850 Edition 2, and IEEE 1588 Time Sync

    View More
  • GE G60 | Generator Protection System

    Comprehensive protection for AC generators. The G60 Generator Protection System, a member of the UR Family of protection relays, provides protection for AC generators. It may be used on any size of generator driven by steam, gas, hydraulic or other turbines.

    View More
  • GPM-S Stator Ground Protection Module

    Sub-harmonic injection based stator ground protection provides early detection of ground fault conditions Detect ground faults through 100% of the stator winding including neutral point

    View More
  • DGPR Retrofit Solution

    Fully integrated retrofit solution of GE's legacy Multilin DGP Generator Protection Relay Suited for large hydro, gas and steam turbine generators

    View More
  • P348 - Variable Speed Double Fed Induction Machine Protection IED

    Advanced variable speed generator management relay Process bus inputs for connection to non-conventional CTs Low frequency protection of the rotor and stator from 0.1-70Hz

    View More
  • P391 Rotor Earth Fault Module

    Detects rotor earth fault faults in the field winding of the generator. Requires the P34x relay to have the current loop CLIO hardware option fitted. Used with P342, P343, P344, P345 and P346 Generator protection relays

    View More
  • W650 Wind Generator Protection System

    Advanced wind turbine protection and control system. W650 Generator Protection System, a member of the 650 Family of protection relays, is a machine controller management device.

    View More
  • P14DG Distributed Generator Interconnection Relay

    Directional Feeder Management relay for small generator protection Available in either a 30TE or 40TE cases TCS and Ethernet communications available together in 40TE case Check sync and voltage restrained overcurrent protection and power function included

    View More
  • P345 Large Generator Management Relay with Stator Earth Fault

    Advanced generator management relay with low frequency injection 100% stator earth fault for large generators Comprehensive generator and transformer protection and condition monitoring Support for a wide range of communication options including MODBUS, IEC60870-5-103, DNP 3.0 and IEC61850

    View More
  • P344 Generator Management Relay with 2 Neutral Voltage Inputs

    Advanced generator management relay with 2 neutral voltage inputs for medium/large generators Comprehensive generator and transformer protection and condition monitoring Support for a wide range of communication options including MODBUS, IEC60870-5-103, DNP 3.0 and IEC61850

    View More
  • P341 Interconnection Protection Relay

    Comprehensive protection for interconnecting distributed resources with the electric power system Provides Dynamic Line Rating (DLR) for transmission line capacity optimization Support for a wide range of communication options including MODBUS, IEC60870-5-103, DNP 3.0 and IEC61850

    View More
  • P342 Small Generator Management IED

    Advanced generator management relay for small generators Programmable curves for easy protection customisation Support for a wide range of communication options including MODBUS, IEC60870-5-103, DNP 3.0 and IEC61850

    View More
  • P343 Medium to Large Sized Generator Management IED

    Advanced generator management relay for medium/large generators Comprehensive generator and transformer protection and condition monitoring Support for a wide range of communication options including MODBUS, IEC60870-5-103, DNP 3.0 and IEC61850

    View More
  • Modem and Accessories

    Two high output power BPL port with integrated 4-port switch with AC and DC power supply Long range version for extra distance coverage without repeaters Coupler and accessories

    View More
  • S20 Managed Ethernet Switch

    Fully flexible layer 2 & 3 Ethernet switch for industrial applications, including PRP redundant networks. Allows up to 24 ports with speeds of up to 1 Gbps, as required in high-end process bus applications. Sub-microsecond accurate time synchronization using IEEE 1588v2 PTP. Modular design, interfaces can be hot-swapped without reconfiguration. Redundant power supply.

    View More
  • Distribution Arrester

    Designed and tested in accordance with the ANSI/IEEE C62.11 and IEC 99-4 standards. Available for L-L system voltages through 36kV. Suitable for both indoor and outdoor applications.

    View More
  • Riser Pole Arrester

    Suitable for both indoor and outdoor applications. Designed and tested in accordance with the latest revision of ANSI/IEEE C62.11 and IEC 9-4.

    View More
  • Surge Protective Device

    Suitable for indoor applications. Design and tested with the 4th edition of UL1449

    View More